The EMOTIV FLEX 2 Saline is an advanced, wireless EEG (Electroencephalography) system designed for scientific research, neurophysiological experiments, and the recording of brain electrical activity. The system utilizes up to 32 Ag/AgCl (silver/silver chloride) recording electrodes with felt elements wetted with saline solution, eliminating the need for traditional conductive gel.
EMOTIV FLEX 2 Saline – 32-Channel Wireless EEG System
The EMOTIV FLEX 2 Saline is an advanced, wireless EEG (Electroencephalography) system designed for scientific research, neurophysiological experiments, and the recording of brain electrical activity. The system utilizes up to 32 Ag/AgCl (silver/silver chloride) recording electrodes with felt elements wetted with saline solution, eliminating the need for traditional conductive gel.
The flexible FLEX cap has 74 holes corresponding to the standard locations of the international 10–20 system, allowing for the individual placement of up to 32 measurement electrodes and two CMS/DRL reference electrodes. This allows for customization of the device configuration to a specific research protocol.
The Saline electrodes can be rehydrated during the study through a special opening in the sensor. This allows for maintaining proper electrode-skin contact without removing the cap. The quality of contact between individual electrodes can be monitored in real time using the EmotivPRO software.
Wireless data transmission, a built-in 9-axis motion sensor, and the ability to freely position the electrodes make the FLEX 2 Saline suitable for both traditional laboratory studies and studies conducted in more natural settings.
Technical Specifications
Number of EEG channels: Up to 32 channels
Number of measurement electrodes: 32 electrodes
Number of reference electrodes: 2
Electrode type: Saline Ag/AgCl – silver/silver chloride
Conducting medium: physiological saline
Electrodes can be rehydrated during the test
Number of felt elements: 80 standard lengths + 20 extended lengths
Electrode felt element diameter: 11 mm
Solution refill hole: 2 mm
Electrode placement: Freely configurable according to the international 10-20 system
Number of cap holes: 74 positions in the 10-20 system
CMS/DRL reference electrodes: Configurable in the 10-20 system locations
Available cap sizes: 54 cm, 56 cm, 58 cm
Cap manufacturer: EasyCap
Sampling method: Sequential, dual ADCs (Analog-to-Digital Converter)
Internal sampling rate: 2048 Hz
EEG output rate: up to 256 SPS (samples per second)
Supported transmission rates: 128 or 256 SPS per channel
Resolution: 16 bits per channel
Voltage resolution: 0.51 µV in 14-bit mode / 0.1275 µV in 16-bit mode
Dynamic range: approximately ±4.17 mV / 8400 µV peak-to-peak
EEG frequency response: 0.16–43 Hz
Digital notch filters: 50 Hz and 60 Hz
Input coupling: AC
Ability to record time-synchronized EEG, ECG/EKG, EMG, and EOG signals
Monitoring Real-time CQ (Contact Quality) electrode contact quality
Built-in motion sensor: 9-axis IMU
IMU chip: ICM-20948
Accelerometer: 3-axis, ±8 g
Magnetometer: 3-axis
Orientation quaternion: 4D
Motion data transfer rate: up to 64 Hz
Wireless communication: Bluetooth 5.2
Communication via dedicated USB receiver: 2.4 GHz
Bluetooth/BLE dongle: included
Charging interface: USB-C
Battery: Built-in 595 mAh lithium-polymer battery
Battery life: up to 6 hours
LED battery level/power indicator
Controller can be placed on the back or top of the cap
Carrying case included.
Software Required for Operation
EMOTIV Launcher – an application used to install, run, and manage the EMOTIV software.
EmotivPRO – the basic software designed to work with FLEX 2 for EEG applications; it allows viewing of EEG signals, checking the quality of electrode contacts, data recording, and analysis.
EmotivPRO Lite – according to the current product page, is available with the purchase of FLEX 2; it allows viewing of raw EEG, movement data, and frequency bands, among other things, but has significant limitations regarding the number of recordings and data export.
Paid EmotivPRO license – required for research applications requiring full recording and export of raw EEG data, including to CSV or EDF formats.
Cortex SDK / Emotiv API – optional, for integrating FLEX 2 with custom software, BCI applications, or research environments. Access to raw EEG data via the API is subject to additional EMOTIV licensing requirements.
System Requirements
Microsoft Windows 10 64-bit, version 1809 or later
Microsoft Windows 11
Apple macOS 12 Monterey or later
FLEX 2 is not supported on Ubuntu and Raspberry Pi, although EMOTIV Launcher is available for some other EMOTIV devices on these platforms.